GEOSigma 125

The highest performing gauge system we have ever developed with unmatched multi-gauge compatibility.

GEOSigma 125 (Web) GEO PSI

GEOSigma 125

The GEOSigma downhole gauge platform is the culmination of over a decade of experience and innovation. Enabling peak monitoring performance, previously unheard-of multi-gauge capability, and reliability designed for the most high-profile downhole completions, this line of downhole gauges is designed for operators who need the most capable monitoring solution available.

Unmatched Reliability

Easy-ConnectTM Cablehead

Multi-Gauge Compatible

Technical Specifications

Built For Reliability

From single gauge applications to high-profile research wells, reliability is key. Our proprietary manufacturing processes and mechanical features ensure our GEOSigma systems are capable of withstanding the extreme vibration and harsh conditions found throughout oil & gas and CCUS wells. And our Patented Easy-ConnectTM 4-Pin Cablehead, utilizes multiple metal-to-metal seals and are pressure testable to ensure reliability prior to deployment.

Available Deployment
Methods

Our GEOSigma gauges can be deployed like any other permanent downhole gauge, as well as below ESP’s using the GEOESP Sigma ESP bridge.

Suspended

Deployment Icon (Suspended) (Multi) GEO PSI

Tubing

Deployment Icon (Tubing) (Multi) GEO PSI

Tubing

Deployment Icon (Casing) (Multi) GEO PSI

Below ESP

Deployment Icon (Tubing) [Below ESP] GEO PSI

The GEOSigma Fail-Safe system provides unparalleled reliability and data integrity for single-string multi-gauge systems.

In typical multi-gauge systems, damage to a cable causing shorting in the system can draw power away from gauges, and kill communications to the entire string. Especially in fracking operations where gauges & cable cemented behind casing are vulnerable to poor cement jobs or misaligned perforating charges, downhole gauge systems are often at risk of complete failure.

Through the use of our exclusive GEOSigma Fail-Safe Modules, selective blocking of data bus lines and power lines to and from each gauge is allowed, eliminating any interference caused by cable shorting. In the event of a short, all gauges above the triggered Fail-Safe Module will continue to operate, whereas other systems would fail entirely.

GEOSigma Fail-Safe Module (Graphic) GEO PSI
Synchronous Sampling GEO PSI

Our groundbreaking GEOSigma technology enables unparalleled capability for advanced distributed pressure monitoring. One such innovation is the ability to sample multiple gauges at the exact same moment! This instantaneous sample of all gauges happens at nearly the speed of light.

This exclusive capability will provide users with never-before-seen pressure and temperature data taken at the exact same time throughout the wellbore. This synchronous data is incredibly useful for frac analysis and advanced reservoir engineering.

Traditional Multi-Gauge Sampling GEO PSI

Traditional Multi-Gauge Sampling

Synchronous Sampling Frac Event GEO PSI

Synchronous Sampling

Compatible With

The GEOSigma gauge is designed for versatility and universal compatibility. Below is a common accessory that is used to complete the GEOSigma monitoring system.

Real-Time Data Applications

Measurement

Products-Downhole-Gauges-Bubble-Tube-System-Measurement-Pressure-Icon-Orange-GEO-PSI

Pressure
(10,000 psi)

The GEOSigma 125 is designed to accurately measure pressure within available ranges between 500 – 10,000 psi.

Products-Downhole-Gauges-Measurement-Temperature-Icon-Orange-GEO-PSI

Temperature
(125°C)

The GEOSigma 125 is designed to accurately measure temperatures up to 125°C (257°F)

Products-Downhole-Gauges-Measurement-Vibration-Icon-Orange-GEO-PSI

Vibration
(± 2g)

The GEOSigma 125 is designed to accurately measure vibration on the X, Y, and Z axis up to ± 2g

Measurement

Pressure, Temperature, & Head-Voltage

Sensor Type

QuartzdyneTM

Output

PSK Telemetry

Input Voltage Range

12-24 VDC

Current

< 10mA

Available Pressure Ranges

10,000 psiA

16,000 psiA

20,000 psiA

25,000 psiA

30,000 psiA

Pressure Accuracy

± 0.015% Full
Scale

± 0.02% Full
Scale

± 0.02% Full
Scale

± 0.02% Full
Scale

± 0.025% Full
Scale

Pressure Resolution

<0.006 psi/
second

<0.008 psi/
second

<0.008 psi/
second

<0.010 psi/
second

<0.010 psi/
second

Pressure Repeatability

<0.01% Full
Scale

<0.01% Full
Scale

<0.01% Full
Scale

<0.01% Full
Scale

<0.01% Full
Scale

Pressure Drift

<0.01% Full
Scale / year

<0.01% Full
Scale / year

<0.01% Full
Scale / year

<0.01% Full
Scale / year

<0.01% Full
Scale / year

Temperature Rating

177°C

Temperature Accuracy

± 0.5°C

Temperature Resolution

<0.005°C / Second

Temperature Repeatability

<0.01°C

Temperature Drift

<0.1°C / year

Construction Material

Inconel 718

Overall Length

20.44” / 519.1mm

Outside Diameter

1.0” / 25.4mm

Minimum Sample Interval

0.1 Seconds

Process Connection

AF1

Surface Communications

Modbus RS486 and 4-20mA Output (1)

Patented Easy-ConnectTM Cablehead

Yes

Leak-Proof Design

Yes

Pressure Testable Design

Yes

Field Programmable

Yes

API Spec Q1 & ISO Certified
Manufacturing

Yes

Smart Technologies

Live transmitting of: Serial No ID, and Valid Data Packets/CRC Errors

Multi-Gauge Compatible

Up to 10 sensors (In any combination of GEOP or GEOQ) on a single downhole tubing encapsulated cable (TEC) (2)

(1) via G6 Interface Card
(2) Our GEOP and GEOQ gauges feature dual pressure and temperature capabilities, each housing two sensors in a single gauge

Looking for the necessary components to build a complete fit for purpose system for your well?

Fill out this short questionnaire and one of our experienced team members will show you a solution designed to match the specific requirements of your well.

Visit this page on desktop to complete a brief questionnaire, or visit our contact page to get in touch with one of our experienced team members.

Contact Information

Provide us with the necessary contact, and location information.


 

 

Downhole Conditions

Tell us about the downhole environment present in your well.


 

Please describe the type of environment the sensors will be in.

 

 

Packer/Obstruction #1

Packer/Obstruction #2

Packer/Obstruction #3

 

Completion Data

Please provide us with as much information on your specific completion as possible.


Surface Casing

 

Production Casing

2nd Production Casing

Tubing

2nd Tubing

Liner

 

 

Open Hole

 

 

What are the major application(s) for the downhole sensor(s)?

What are your preferred wellhead exit options?

What are the surface electronics required?

 

 

 

 

 

Want to know more?