P105 SRO

A cost-effective analog downhole sensor designed to accurately measure real-time pump intake pressure or fluid level.

Products-Downhole-Gauges-Analog-Gauges-P105-SRO-PT105-SRO-GEO-PSI

P105 SRO – Permanent Downhole Gauge

The GEO PSI IECEx certified 4-20mA pressure gauge is the first cost-effective solution designed for measuring real-time pump intake pressure for artificial lift systems in oil & gas wells. This gauge is able to withstand vibrational forces exerted by high horsepower progressive cavity, rod, and ESP pumps.

Easy Connect Cablehead

Leak Proof Design

Intrinsically Safe

IECEx Certified

Products-Downhole-Gauges-Analog-Gauges-P105-SRO-PT105-SRO-GEO-PSI

P105 SRO – Permanent Downhole Gauge

The GEO PSI IECEx certified 4-20mA pressure gauge is the first cost-effective solution designed for measuring real-time pump intake pressure for artificial lift systems in oil & gas wells. This gauge is able to withstand vibrational forces exerted by high horsepower progressive cavity, rod, and ESP pumps.

Easy Connect Cablehead

Leak Proof Design

Intrinsically Safe

IECEx Certified

Real-Time Data Applications

  • Pump Intake Pressure Measurment for Rod Pump, PCP, and ESP
  • Fluid Level Measurment
  • Bottomhole Pressure
  • Artificial Lift Optimization
  • Hydrology
  • Observation Wells
  • Suspended Depolyments
  • Tubing Conveyed

Measurement

Products-Downhole-Gauges-Bubble-Tube-System-Measurement-Pressure-Icon-Orange-GEO-PSI

Pressure (3,000 psi)

The P105 SRO is designed to accurately measure pressure within available ranges between 50 - 3,000 psi.

Output

4-20 mA

Input Voltage Range

8-30 VDC

Avalible Pressure Ranges

50  300  500  1,000  1,500  2,000  3,000 psiA

Proof Pressure

6,000 psi

Temperature Range

-40°C to 105°C (-40°F to 221°F)

Accuracy

± 0.1% full scale error best fit straight line. Typical average error (1) ± 0.16% full scale (5 point verification at 20°C)

Long Term Vibration Resiliency

8g at 100 Hz measured peak-to-peak (2)

Compatible TEC Cables

0.160″ / 4mm single conductor

Construction Material

Stainless Steel 316L

Outside Diameter

0.95″ / 24.13mm

Process Connection

1/4″ NPT Male

Length

7.75″ / 196.85mm measured from process connection to top of pressure testable cablehead

Certifications

IECEx Ex ia IIB T3 Ga (3)(4) intrinsically safe. Tamb = -20°C to 105°C (-4°F to 221°F)

Applicable Standards

IEC 60079-0: 2007-10
IEC 60079-11: 2006

Patented Easy-Connect Cablehead System

Yes

Leak Proof Design

Yes

Pressure Testable Design

Yes

(1) Average error is calculated from a sample batch of 100 units. All errors are expressed as a positive value to calculate the average, maximum allowable single error is ± 0.5% absolute full-scale.
(2) 14-day bench test.
(3) GEO PSI certificate number: IECEx QPS 15.0013x is avalible at www.IECEX.com.
(4) When installed according to approved instruction manual.

Pressure Rating

Product Number

50 psiA

101505

200 psiA

101503

300 psiA

101504

500 psiA

101417

1,000 psiA

101418

1,500 psiA

100128

2,000 psiA

101419

3,000 psiA

100126

Looking for the necessary components to build a complete fit for purpose system for your well?

Fill out this short questionnaire and one of our experienced team members will show you a solution designed to match the specific requirements of your well.

Visit this page on desktop to complete a brief questionnaire, or visit our contact page to get in touch with one of our experienced team members.

Contact Information

Provide us with the necessary contact, and location information.


 

 

Downhole Conditions

Tell us about the downhole environment present in your well.


 

Please describe the type of environment the sensors will be in.

 

 

Packer/Obstruction #1

Packer/Obstruction #2

Packer/Obstruction #3

 

Completion Data

Please provide us with as much information on your specific completion as possible.


Surface Casing

 

Production Casing

2nd Production Casing

Tubing

2nd Tubing

Liner

 

 

Open Hole

 

 

What are the major application(s) for the downhole sensor(s)?

What are your preferred wellhead exit options?

What are the surface electronics required?

 

 

 

 

 

  • Your email is safe with us.

Output

4-20 mA

Input Voltage Range

8-30 VDC

Avalible Pressure Ranges

50  300  500  1,000  1,500  2,000  3,000 psiA

Proof Pressure

6,000 psi

Temperature Range

-40°C to 105°C (-40°F to 221°F)

Accuracy

± 0.1% full scale error best fit straight line. Typical average error (1) ± 0.16% full scale (5 point verification at 20°C)

Long Term Vibration Resiliency

8g at 100 Hz measured peak-to-peak (2)

Compatible TEC Cables

0.160″ / 4mm single conductor

Construction Material

Stainless Steel 316L

Outside Diameter

0.95″ / 24.13mm

Process Connection

1/4″ NPT Male

Length

7.75″ / 196.85mm measured from process connection to top of pressure testable cablehead

Certifications

IECEx Ex ia IIB T3 Ga (3)(4) intrinsically safe. Tamb = -20°C to 105°C (-4°F to 221°F)

Applicable Standards

IEC 60079-0: 2007-10
IEC 60079-11: 2006

Patented Easy-Connect Cablehead System

Yes

Leak Proof Design

Yes

Pressure Testable Design

Yes

(1) Average error is calculated from a sample batch of 100 units. All errors are expressed as a positive value to calculate the average, maximum allowable single error is ± 0.5% absolute full-scale.
(2) 14-day bench test.
(3) GEO PSI certificate number: IECEx QPS 15.0013x is avalible at www.IECEX.com.
(4) When installed according to approved instruction manual.

Pressure Rating

Product Number

50 psiA

101505

200 psiA

101503

300 psiA

101504

500 psiA

101417

1,000 psiA

101418

1,500 psiA

100128

2,000 psiA

101419

3,000 psiA

100126

Looking for the necessary components to build a complete fit for purpose system for your well?

Fill out this short questionnaire and one of our experienced team members will show you a solution designed to match the specific requirements of your well.

Visit this page on desktop to complete a brief questionnaire, or visit our contact page to get in touch with one of our experienced team members.

Contact Information

Provide us with the necessary contact, and location information.


 

 

Downhole Conditions

Tell us about the downhole environment present in your well.


 

Please describe the type of environment the sensors will be in.

 

 

Packer/Obstruction #1

Packer/Obstruction #2

Packer/Obstruction #3

 

Completion Data

Please provide us with as much information on your specific completion as possible.


Surface Casing

 

Production Casing

2nd Production Casing

Tubing

2nd Tubing

Liner

 

 

Open Hole

 

 

What are the major application(s) for the downhole sensor(s)?

What are your preferred wellhead exit options?

What are the surface electronics required?

 

 

 

 

 

  • Your email is safe with us.

Want to know more?

One of our team members would be happy to help.